Bulk Walk In Shower Enclosures and the Screen Width a Splash Needs

share:
November 25,2026

Walk in shower enclosures need a screen about 980 mm wide at a 2,100 mm head height: water leaves the rose with roughly 1.5 metres a second of sideways speed and falls 2.1 metres in 0.65 seconds, which puts it 980 mm from the head. An 800 mm panel leaves 180 mm of floor wet.

The jet sets the screen width

Three inputs and one formula: outlet height, the horizontal speed of the spray, and gravity. At 2,100 mm and 1.5 metres a second the throw is 980 mm. Nothing about the tray size or the tile module enters the number.

walk in shower enclosures with a fixed glass panel and no door in a hotel bathroom

How far does water travel sideways before it reaches the floor?

Treat the outer edge of the spray as a projectile. A rose mounted at 2,100 mm above the finished floor drops its water 2.1 metres, and the fall time is the square root of twice the height over gravity, which is 0.654 seconds. The horizontal distance is the sideways speed multiplied by that time, so the whole question collapses to one number: how fast the jet leaves the rose.

A fixed rose at 9 litres a minute through a 100 mm face throws its outer droplets at 1.2 to 1.8 metres a second, depending on the nozzle pattern and the supply pressure. Put the three speeds through the formula: 0.79 metres at 1.2, 0.98 at 1.5, and 1.18 at 1.8. That band is the wet zone, and it is measured from the centre line of the head.

Height matters less than buyers expect, because the fall time moves with the square root of the height. Go from 2,000 to 2,200 mm and the throw at 1.5 metres a second goes from 0.96 to 1.00 metre. Speed matters more: 1.2 to 1.8 metres a second moves the same throw from 0.79 to 1.18, which is half a screen width.

Which screen width covers that distance at a 2,100 mm head?

Walk in shower enclosures have no door, so the screen is the only thing between the wet zone and the rest of the bathroom. Compare the panel width against the throw, measured from the head to the free edge of the glass. A 1,000 mm panel covers the 1.5 metres a second case with 20 mm to spare, and an 800 mm panel leaves 180 mm of the wet zone outside the glass.

Panel width Head at 2,000 mm Head at 2,100 mm Head at 2,200 mm
700 mm wets 60 mm wets 80 mm wets 100 mm
800 mm dry by 40 mm wets 180 mm wets 200 mm
900 mm dry by 140 mm wets 80 mm wets 100 mm
1,000 mm dry by 240 mm dry by 20 mm level
1,200 mm dry by 440 mm dry by 220 mm dry by 200 mm

Throw taken at 1.5 metres a second sideways, which is the middle of the 1.2 to 1.8 band, from the head centre line to the glass edge. Arithmetic on the stated heights. Calculated, not measured.

That table explains a pattern buyers notice and rarely get explained: the 800 mm panel that works in a showroom fails in a hotel because the showroom head sits at 1,900 mm on a low ceiling. If the screen cannot grow, the alternatives are a frameless swing shower door that closes the gap, or a head moved to the far wall so the throw points away from the opening.

What does the floor have to do while the screen holds the splash?

The tray under walk in shower enclosures has to move water away from the opening, and it does that with fall. At 1:80, which is the common shower fall, a 1,000 mm run drops 12.5 mm. That number fixes two things: the depth of the recess at the far end, and how much of a lip the entry can have before it becomes a step.

Put the two together. The 180 mm of wet floor that an 800 mm panel leaves sits right where the fall is weakest, at the entry, and 12.5 mm of fall across a 1,000 mm tray only holds a film about 1.5 mm deep over that tray before water starts to spread, which is 1.5 litres. A linear drain at the far wall keeps that film moving; a 50 mm centre outlet under the entry works against it.

EN 14428 is the product standard for shower enclosures and it tests the enclosure, so the fall and the drain belong to the tray and the tiling package. The question that decides whether a shower door layout works on site is therefore asked of the wet trades, and it should be asked before the glass is ordered.

walk in shower panel wall bracket and glass edge detail

How much glass is hanging on the wall brackets?

On walk in shower enclosures the glass weighs 2.5 kilograms per square metre per millimetre, so a 1,000 by 2,000 mm panel is 2.0 square metres: 40 kilograms at 8 mm and 50 at 10 mm. Two brackets carry that as a cantilever, and the load path runs into whatever the wall is made of, which is where walk in shower enclosures fail in service.

Two order lines follow. The bracket and the stabiliser bar should be stainless to EN 10088-1 and come with an EN 10204 inspection document, because a zinc plated bracket in a wet room is a two year part. And the fixing has to be specified: into a stud, into a solid wall, or through tile into a substrate that will hold 50 kilograms at a lever arm of 1,000 mm.

Where the opening runs past 1,200 mm the cantilever stops being the cheap answer, and a moving panel takes half the span: a single sliding shower door hangs its weight on a top rail, so one wall bracket carries half of what a fixed panel would put on it, which is why 1,500 mm hotel openings tend to order it at 10 mm glass.

double glazing triple glazing low e and laminated glass options

Which bathroom needs a door more than a wider screen?

Three cases. A room where the 1,000 mm panel would leave less than 600 mm to pass, a ceiling that puts the head above 2,200 mm where the throw at 1.8 metres a second reaches 1.21 metres, and a shared wall where spray on the far side of the screen is not acceptable at any width. In all three the door closes a gap that width cannot. A frameless shower buyer guide is worth reading against the plan before the decision is taken.

If the bathroom plan and the head height are known, send them over and the panel width, the glass thickness and the bracket type come back against that plan, with the wet zone drawn on it.

What belongs on the order sheet for a level access tray?

Five lines carry a walk in shower enclosures order: panel width and height, glass thickness and edge finish, head height on the drawing, bracket and stabiliser type, and the fall direction of the tray. The third line is the one that gets left out and the one that decides whether the screen is wide enough.

Commercially, an order for walk in shower enclosures stays simple. Minimum order is 10-20 units and lead time is 25-30 days from an approved drawing, which leaves room to check the head height against the ceiling before the glass is cut.

Parameter Typical value Note
Product walk in shower enclosures frameless, one fixed panel, no door
Panel width 800 to 1,200 mm sized by the throw, 980 mm at a 2,100 mm head
Panel height 2,000 mm checked against the ceiling and the head
Glass 8 or 10 mm toughened to EN 12150-1, 40 or 50 kg for a 2 sqm panel
Glass impact class 1 or 2 to EN 12600 state the class on the quotation
Tray fall 1:80 12.5 mm over 1,000 mm, away from the entry
Brackets stainless to EN 10088-1 with an EN 10204 document
Product standard EN 14428 tested as an enclosure, not as an installation
Minimum order 10-20 units lead time 25-30 days

Panel width is arithmetic on the stated head height and spray speed. Glass thickness, bracket type and tray fall are confirmed on the approved drawing for the project.

Frequently asked questions

What is the wholesale price for walk in shower enclosures quoted from? From the panel width and height, the glass thickness and the bracket set, per unit. Panel width is the line that moves first, because the head height sets it and the tray has no say in it.

Can an 800 mm panel be used at a 2,100 mm head height? It covers 800 mm of a 980 mm throw at 1.5 metres a second, so 180 mm of floor inside the tray stays wet. With a head at 1,900 mm and set on the far wall, the same panel works.

What is the minimum order and lead time? Minimum order is 10-20 units and lead time is 25-30 days from an approved drawing. Projects that mix 8 and 10 mm glass on one floor are priced per thickness, because the drilling and the brackets differ.

Which supplier figure should be checked first? The panel width against the head height on the drawing. A supplier who quotes a width without asking for the head height is quoting a panel, and the wet floor is left to the client to discover.

Ordering from Haolv

Haolv Building Materials Co., Ltd. has been making doors and windows for 19 years. Walk in shower enclosures are assembled from 8 or 10 mm toughened glass to EN 12150-1, with stainless brackets and a stabiliser bar. Certification is available on request with the quotation. Minimum order is 10-20 units and lead time is 25-30 days.

Send the bathroom plan with the head height marked to kristin@haolvbuilding.com, or start from Haolv Building Materials Co., Ltd. and the panel width comes back with the wet zone marked on the plan.

What this page calculates and what it leaves to the project: the 0.654 seconds, the 0.79, 0.98 and 1.18 metres, the 12.5 mm of fall and the 40 and 50 kilograms are arithmetic on a stated head height, a stated spray speed and a stated glass thickness. They are calculated, not measured. The spray speed of a specific rose, the fall of a specific tray and the capacity of a specific wall fixing are confirmed on site and on the approved drawing.

Haolv Building Materials test reports and product certification wall

References

  1. EN 14428:2015+A1:2018 — Shower enclosures. Functional requirements and test methods.
  2. EN 12150-1:2015 — Glass in building. Thermally toughened soda lime silicate safety glass.
  3. EN 12150-2:2004 — Glass in building. Thermally toughened soda lime silicate safety glass. Evaluation of conformity.
  4. EN 14179-1:2016 — Glass in building. Heat soaked thermally toughened soda lime silicate safety glass.
  5. EN 12600:2002 — Glass in building. Pendulum test. Impact test method and classification for flat glass.
  6. EN 1096-1:2012 — Glass in building. Coated glass. Definitions and classification.

The throw distances, the fall and the weights in this guide are arithmetic on a stated head height, a stated spray speed and a stated glass thickness. They are calculations from a drawing, not measurements taken in a bathroom, and the impact class of any panel is taken from the test report for that glass.

GET A QUOTE