Flush sash aluminium windows trade 8 to 10 mm of sash overlap for a level facade, and that overlap is the part that normally sheds water. Two 30 by 4 mm drain slots pass 0.026 litres a second at 4 mm of head, which covers a 1.2 square metre window under 100 mm an hour of rain. Slot count is the number to check before the profile.
The slot budget in three lines
Rain on the face is not the water the slots see. At 100 mm an hour a 1.2 square metre opening puts 0.033 litres a second onto the glass, and one 30 by 4 mm slot passes Q = 1.705 x b x h^1.5 = 0.0129 litres a second. Three slots carry 0.039, so on flush sash aluminium windows the count decides the result and the width of the slot only trims it.

In this guide:
An outward opening casement stands 8 to 12 mm proud of the frame. Water running down the glass meets that step and breaks away from the joint, and the closing plane behind it carries a 14 to 18 mm rebate that the sash presses a seal against. A flush sash design moves the sash into the frame plane, so the rebate turns a corner and the straight line the water has to cross on its way in falls to 6 to 8 mm.
Halving the overlap sounds fatal and is not, because the overlap was never what held the water out. Capillary rise in a 0.3 mm gap reaches 2 x 0.072 / (1000 x 9.81 x 0.00015) = 98 mm, and in a 0.15 mm gap it reaches 196 mm. Both figures exceed any rebate dimension cut into a window. The overlap buys turbulence and distance; the slots do the draining. Buyers weighing flush against non flush casements are comparing how much slot area each frame can hide.
On flush sash aluminium windows the design rain of 100 mm an hour over a 1.2 square metre opening is 0.1 x 1.2 = 0.12 cubic metres an hour, or 0.033 litres a second on the face. Only the share that lands on the glass and runs to the bottom rebate reaches the slots, and that share is smaller than the face figure. A slot budget is still written against the whole face, because wind drives rain sideways onto surfaces that would stay dry in still air.
A slot on flush sash aluminium windows behaves as a weir, so Q = 1.705 x b x h^1.5 with b and h in metres. At 30 mm wide and 4 mm of head that is 0.0129 litres a second per slot. The same slot at 6 mm of head passes 0.0238, which is why a deeper bottom rebate can halve the slot count on the same window.
| Opening | Face load at 100 mm/h | Slots at 4 mm head | Capacity | Margin |
|---|---|---|---|---|
| 900 x 1,200 mm, 1.08 sqm | 0.030 L/s | 3 | 0.039 L/s | 29% |
| 1,000 x 1,200 mm, 1.20 sqm | 0.033 L/s | 3 | 0.039 L/s | 17% |
| 1,200 x 1,400 mm, 1.68 sqm | 0.047 L/s | 4 | 0.052 L/s | 11% |
| 1,500 x 1,500 mm, 2.25 sqm | 0.063 L/s | 5 | 0.065 L/s | 4% |
| 2,400 x 1,400 mm, 3.36 sqm | 0.093 L/s | 8 | 0.104 L/s | 11% |
Face load = area x 100 mm an hour. Slot = 30 x 4 mm weir, Q = 1.705 x b x h^1.5. Every row is arithmetic on a stated area and a stated rain intensity, calculated, not measured. The site rain intensity sets the column; the slot count follows from it.

A slot drains while the chamber behind it sits at outside pressure. Seal the chamber and wind pressure pushes water up the inner leg until the inner seal becomes the barrier. At the EN 12208 class 9A test pressure of 600 Pa the head is 600 / 9810 = 61 mm of water, so an unvented chamber asks one seal to hold a 61 mm column on every gust.
That is why a flush frame carries two legs and a vented outer chamber: the outer leg screens the water, the chamber vents to outside, and the inner ethylene propylene leg seals air. Air performance is classified apart from water, and stormproof casements reach class 4 of EN 12207, which is 3 cubic metres an hour per square metre at 100 Pa, with the same two leg layout.
Slot blockage. A 30 by 4 mm slot collects leaf litter and insect cases, and the weir equation is linear in width, so half the width is half the capacity at the same head. On a 1.2 square metre flush sash aluminium windows opening, two of three slots blocked takes capacity from 0.039 to 0.013 litres a second, under the 0.033 face load, and the first symptom is a damp patch on the reveal at the hinge side.
The second is the bottom seal. EPDM takes about 25 percent compression set, so a 1.8 mm design compression is 1.35 mm after ageing, while a plasticised PVC leg at 50 percent set leaves 0.90 mm. The bottom leg is the one that sits in water. Specify EPDM on the three lower sides, and check that the end slots sit within 50 mm of each corner, because water pools at the corners before it reaches the middle.

A flush system stacks three things into the depth a standard casement uses for one: the sash, the closing rebate and the drainage chamber. Most flush sash aluminium windows systems run 70 to 76 mm for that reason, and german style casements in the same family are quoted at 76 mm with a 70 mm sightline.
The consequence lands on the wall and not on the window. A 100 mm masonry wall with 15 mm of plaster each side leaves 70 mm of reveal, which is the frame depth with nothing left for the foam backer. On a 70 mm wall the frame stands proud of the internal face, and the flush line the design was bought for disappears at the first internal corner.
Six lines carry the order: opening sizes, frame depth with sightline, slot count and position per leaf, glass build-up with its U-value, seal material per side, and the design rain intensity the slot count was checked against. The sixth line is what turns a slot count into a decision. At 60 mm an hour a three slot budget is generous; at 150 mm an hour the same window needs 6 mm of head or a fourth slot.
Where an elevation takes driving rain and the reveal is shallow, top hung outward windows keep the outward step that a flush design gives up, and mixing the two on one facade is normal on coastal work. If the opening list with the wall build-up is on file, send it over and the slot count and frame depth come back per opening, checked against the rain intensity for that site.
| Parameter | Typical value | Note |
|---|---|---|
| Product | flush sash aluminium windows | sash face level with the outer frame |
| Profile | 6063-T5, frame depth 70 to 76 mm | PA66 GF25 thermal break where specified |
| Glass | double glazed 4-16-4, U-value 1.2 to 1.6 W/(sqm K) | low-e and argon on cold elevations |
| Seals | EPDM on the three lower sides | plasticised PVC takes a higher compression set |
| Drainage | 30 x 4 mm slots, 3 to 5 per leaf | checked against the site rain intensity |
| Water tightness | EN 12208, class stated per project | class 9A test pressure is 600 Pa |
| Air permeability | EN 12207, class 4 available | 3 m3/(h sqm) at 100 Pa |
| Product standard | EN 14351-1 | declaration per order |
| Minimum order | 10-20 units | lead time 25-30 days |
Slot counts and frame depths are quoted per opening from the site rain intensity and the wall build-up. The capacities in this guide are weir arithmetic on a stated slot and head, calculated, not measured.
What sets the wholesale price of bulk flush sash aluminium windows? Frame depth, slot and seal detail, glass build-up and hardware. The slot count is quoted per opening, so two windows of the same size on different elevations can carry different drainage detail and different prices.
How many drain slots should each leaf have? On flush sash aluminium windows, three on a 1.2 square metre leaf at 4 mm of head, four above 1.6 square metres, and one more for every additional 0.5 square metre. Ask for the count in writing with the rain intensity it was checked against.
Does a flush sash leak more than a standard casement? The overlap is 6 to 8 mm against 14 to 18 mm, so the reserve is smaller, and the slot budget has to be larger to reach the same water tightness class. A flush frame with three 30 by 4 mm slots carries more water off a 1.2 square metre window than a stormproof frame with one.
What is the minimum order and lead time? Minimum order is 10-20 units and lead time is 25-30 days from an approved drawing. Windows that share a slot layout and a glass build-up are cut in one batch, so splitting an order across two drainage details adds a separate run.
Haolv Building Materials Co., Ltd. has been making doors and windows for 19 years. Flush sash aluminium windows are built on 6063-T5 sections, glazed to EN 14351-1 and supplied with the slot layout, the seal schedule and the water tightness class written on the drawing. Certification is available on request with the quotation. Minimum order is 10-20 units and lead time is 25-30 days.
Send the opening list with the wall build-up to kristin@haolvbuilding.com, or start from Haolv Building Materials Co., Ltd. and the drainage detail comes back per elevation.
What this page calculates and what a project confirms: the 0.0129 litre a second per slot, the 0.033 face load, the 61 mm head behind a 600 Pa gust and the 98 mm capillary rise are arithmetic on a stated slot, a stated area, a stated pressure and a stated gap. They are calculated, not measured. The rain intensity, the slot detail and the water tightness class of a specific order come from the site weather data, the approved drawing and the test report of that build-up.

The slot capacities, face loads, capillary heights and pressure heads in this guide are arithmetic on a stated slot size, a stated opening area, a stated rain intensity and a stated pressure. They are calculated, not measured. Actual performance depends on the site rain intensity, the slot position on the approved drawing and the compression set of the seal fitted.
Fast simple channel to send demands lock favorable price for building window door bulk purchases.